Zum Hauptinhalt wechseln

Was du brauchst

Dieser Teardown ist keine Reparaturanleitung. Um dein Logitech Webcam Pro 9000 zu reparieren, verwende unsere Fehlerbehebungsseite.

  1. Logitech Webcam Pro 9000 Teardown, Logitech Webcam Pro 9000 Teardown: Schritt 1, Bild 1 von 2 Logitech Webcam Pro 9000 Teardown, Logitech Webcam Pro 9000 Teardown: Schritt 1, Bild 2 von 2
  2. Logitech Webcam Pro 9000 Teardown: Schritt 2, Bild 1 von 2 Logitech Webcam Pro 9000 Teardown: Schritt 2, Bild 2 von 2
    • Remove screws where shown by the green arrows.

  3. Logitech Webcam Pro 9000 Teardown: Schritt 3, Bild 1 von 2 Logitech Webcam Pro 9000 Teardown: Schritt 3, Bild 2 von 2
    • Remove e-ring to detach grommet.

  4. Logitech Webcam Pro 9000 Teardown: Schritt 4, Bild 1 von 3 Logitech Webcam Pro 9000 Teardown: Schritt 4, Bild 2 von 3 Logitech Webcam Pro 9000 Teardown: Schritt 4, Bild 3 von 3
    • Remove screws indicated by the green arrows.

    • Do not remove the screws indicated by the red arrows at this point.

    • Autofocus system contains magnets.

  5. Logitech Webcam Pro 9000 Teardown: Schritt 5, Bild 1 von 3 Logitech Webcam Pro 9000 Teardown: Schritt 5, Bild 2 von 3 Logitech Webcam Pro 9000 Teardown: Schritt 5, Bild 3 von 3
    • Remove cover.

  6. Logitech Webcam Pro 9000 Teardown: Schritt 6, Bild 1 von 1
  7. Logitech Webcam Pro 9000 Teardown: Schritt 7, Bild 1 von 3 Logitech Webcam Pro 9000 Teardown: Schritt 7, Bild 2 von 3 Logitech Webcam Pro 9000 Teardown: Schritt 7, Bild 3 von 3
    • The screws indicated in red can now be removed. The screws are glued into place and removal can be assisted by heating gently with a soldering iron.

    • Autofocus motor connections can be removed by desoldering using desoldering braid where indicated.

  8. Logitech Webcam Pro 9000 Teardown: Schritt 8, Bild 1 von 3 Logitech Webcam Pro 9000 Teardown: Schritt 8, Bild 2 von 3 Logitech Webcam Pro 9000 Teardown: Schritt 8, Bild 3 von 3
    • Almost done.

  9. Logitech Webcam Pro 9000 Teardown: Schritt 9, Bild 1 von 3 Logitech Webcam Pro 9000 Teardown: Schritt 9, Bild 2 von 3 Logitech Webcam Pro 9000 Teardown: Schritt 9, Bild 3 von 3
    • The lens can be fully removed from the autofocus mount.

    • The infrared filter looks to be difficult to remove.

    • Further disassembly appears to be challenging.

    • They did not need to glue it on because the magnets held it in place.

    • The camera was fully reassembled and works.

I Heart Robotics

Mitglied seit: 11/09/09

210 Reputation

3 Anleitungen geschrieben

2 Kommentare

The IR filter can be removed.

Wear eye protection.

Take a sharp pocket knife or utility knife and slowly, carefully score around the edge of the IR filter where it bumps up against the inside of the round lens body. Keep doing this around and around and around. Remove shards of material every couple of passes.

Try slipping a very thin jewelers screwdriver under the filter at various points along the edge where you have scored. If it does not get in, repeat steps above.

At some point enough of the filter will have been removed by the scoring process that you can slip the screwdriver (or whatever thin prying instrument you can think of) under the filter, and lever against the lens body to pop it out.

You will not be able to put it back in. Or if you can, I don't know how because I did not need to for my purposes.

Benjamin Cox - Antwort

I cut out the IR filter with a box cutter. Cut 1mm from the end at a 45 degree angle while holding the lens in place. The filter comes off after a few tries. Be sure to cut off any rough edges, as the debris can fall ontop of the image sensor and cause dark cluster defects.