Zum Hauptinhalt wechseln

Sony Cyber-shot DSC-W290 Flash Bulb Assembly Replacement

Was du brauchst

  1. Sony Cyber-shot DSC-W290 Flash Bulb Assembly Replacement, Battery: Schritt 1, Bild 1 von 1
    • Find the hatch labeled "open" on the left side of the bottom of the camera.

    • Slide the hatch in the direction that the arrow is pointing. The hatch will open outward on its own.

  2. Sony Cyber-shot DSC-W290 Flash Bulb Assembly Replacement: Schritt 2, Bild 1 von 1
    • Slide the blue locking tab to release the battery.

    • Slide the battery out of the camera.

  3. Sony Cyber-shot DSC-W290 Flash Bulb Assembly Replacement, Outer Casing: Schritt 3, Bild 1 von 2 Sony Cyber-shot DSC-W290 Flash Bulb Assembly Replacement, Outer Casing: Schritt 3, Bild 2 von 2
    • Replace hatch and rotate camera 180 degrees. You should still be looking at the bottom of the camera.

    • Remove the four 2.5mm Phillips #0 screws.

  4. Sony Cyber-shot DSC-W290 Flash Bulb Assembly Replacement: Schritt 4, Bild 1 von 3 Sony Cyber-shot DSC-W290 Flash Bulb Assembly Replacement: Schritt 4, Bild 2 von 3 Sony Cyber-shot DSC-W290 Flash Bulb Assembly Replacement: Schritt 4, Bild 3 von 3
    • Turn the camera so the left side-panel reading "5x Optical Zoom" faces you.

    • Remove the two 2.5mm Phillips #0 screws.

    • You may have to remove the screws with a pair of tweezers when the screws are almost out.

  5. Sony Cyber-shot DSC-W290 Flash Bulb Assembly Replacement: Schritt 5, Bild 1 von 3 Sony Cyber-shot DSC-W290 Flash Bulb Assembly Replacement: Schritt 5, Bild 2 von 3 Sony Cyber-shot DSC-W290 Flash Bulb Assembly Replacement: Schritt 5, Bild 3 von 3
    • Turn the camera so the right side faces you.

    • Remove the two 2.5mm Phillips #0 screws.

    • You may have to remove the screws with a pair of tweezers when the screws are almost out.

  6. Sony Cyber-shot DSC-W290 Flash Bulb Assembly Replacement: Schritt 6, Bild 1 von 1
    • Rotate camera so that the back is facing you.

    • Pull the back casing directly away from the LCD screen.

  7. Sony Cyber-shot DSC-W290 Flash Bulb Assembly Replacement: Schritt 7, Bild 1 von 2 Sony Cyber-shot DSC-W290 Flash Bulb Assembly Replacement: Schritt 7, Bild 2 von 2
    • Turn the camera so that the left side is facing you.

    • Pull the left side-panel off of the camera.

  8. Sony Cyber-shot DSC-W290 Flash Bulb Assembly Replacement: Schritt 8, Bild 1 von 2 Sony Cyber-shot DSC-W290 Flash Bulb Assembly Replacement: Schritt 8, Bild 2 von 2
    • Turn camera so that the front of the camera is facing you.

    • Pull the front casing directly away from the camera.

    • The right side panel may fall off when you take the front panel off.

  9. Sony Cyber-shot DSC-W290 Flash Bulb Assembly Replacement: Schritt 9, Bild 1 von 2 Sony Cyber-shot DSC-W290 Flash Bulb Assembly Replacement: Schritt 9, Bild 2 von 2
    • Turn the camera so that the right side is facing you.

    • Pull the right side-panel away from the rest of the camera.

  10. Sony Cyber-shot DSC-W290 Flash Bulb Assembly Replacement: Schritt 10, Bild 1 von 2 Sony Cyber-shot DSC-W290 Flash Bulb Assembly Replacement: Schritt 10, Bild 2 von 2
    • This is what your camera should look like now that you have removed the casing from all sides.

  11. Sony Cyber-shot DSC-W290 Flash Bulb Assembly Replacement, LCD Assembly: Schritt 11, Bild 1 von 1
    • Gently pull the LCD and its casing away from the motherboard as shown.

    • Be careful not to rip out any ribbon cables.

  12. Sony Cyber-shot DSC-W290 Flash Bulb Assembly Replacement: Schritt 12, Bild 1 von 2 Sony Cyber-shot DSC-W290 Flash Bulb Assembly Replacement: Schritt 12, Bild 2 von 2
    • Disconnect the small ribbon-wire by gently pulling on the small ribbon-wire where it connects with the motherboard.

    • Do not use excessive force to remove the wire because this may cause it to tear.

  13. Sony Cyber-shot DSC-W290 Flash Bulb Assembly Replacement: Schritt 13, Bild 1 von 2 Sony Cyber-shot DSC-W290 Flash Bulb Assembly Replacement: Schritt 13, Bild 2 von 2
    • Disconnect the large ribbon-wire by pulling on the large ribbon-wire where it connects to the motherboard.

  14. Sony Cyber-shot DSC-W290 Flash Bulb Assembly Replacement: Schritt 14, Bild 1 von 1
    • Pull the LCD and its casing away from the rest of the camera.

  15. Sony Cyber-shot DSC-W290 Flash Bulb Assembly Replacement, Flash Bulb Assembly: Schritt 15, Bild 1 von 2 Sony Cyber-shot DSC-W290 Flash Bulb Assembly Replacement, Flash Bulb Assembly: Schritt 15, Bild 2 von 2
    • Turn the camera so the back is facing you.

    • Remove the 2.5mm Philips #0 screw at the top of the camera.

  16. Sony Cyber-shot DSC-W290 Flash Bulb Assembly Replacement: Schritt 16, Bild 1 von 3 Sony Cyber-shot DSC-W290 Flash Bulb Assembly Replacement: Schritt 16, Bild 2 von 3 Sony Cyber-shot DSC-W290 Flash Bulb Assembly Replacement: Schritt 16, Bild 3 von 3
    • Tilt top casing up and towards you.

    • Carefully remove the right ribbon-wire from the top camera panel by pulling where the wire connects to the top.

    • Make sure to hold the camera with your thumb on the white square to ensure the ribbon-wire is not disconnected from the motherboard.

    • Carefully remove the left ribbon-wire from the top camera panel by pulling where the wire connects to the top.

Abschluss

To reassemble your device, follow these instructions in reverse order.

Ein:e weitere:r Nutzer:in hat diese Anleitung absolviert.

Evan Mayer

Mitglied seit: 10/05/10

318 Reputation

5 Anleitungen geschrieben

Team

Cal Poly, Team 7-54, Amido Fall 2010 Mitglied von Cal Poly, Team 7-54, Amido Fall 2010

CPSU-AMIDO-F10S7G54

4 Mitglieder

16 Anleitungen geschrieben

0 Kommentare

Kommentar hinzufügen

Seitenaufrufe:

Letzte 24 Stunden: 0

Letzte 7 Tage: 1

Letzte 30 Tage: 3

Insgesamt: 2,275