5. Schritt
Using the capacitor discharge tool carefully touch each end of the capacitor discharge tool to the each terminal of the capacitor.
  • Using the capacitor discharge tool carefully touch each end of the capacitor discharge tool to the each terminal of the capacitor.

  • Click the link below for instructions on how to make the capacitor discharge tool: Ein Entladewerkzeug für Kondensatoren im Eigenbau

  • NEVER touch both both capacitor terminals with just one of the wires. This will create a large potentially dangerous large spark. This will also cause serious damage to the camera.

  • Keep the wires connected to the capacitor terminals for 2 minutes to completely discharge the capacitor

  • The camera should be completely safe to handle now.