Zum Hauptinhalt wechseln

Diese Anleitung enthält neuere Änderungen. Wechsel zur neuesten unüberprüften Version.

Hoover LiNX Replace The Motor Replacement

Was du brauchst

  1. Hoover LiNX  Replace The Motor Replacement, Replace The Motor: Schritt 1, Bild 1 von 1
    • Detach the rolling assembly from the body by pushing the button found at the base.

  2. Hoover LiNX  Replace The Motor Replacement: Schritt 2, Bild 1 von 1
    • Remove the seven 7.5mm Phillips #1 screws from the brush retainer.

  3. Hoover LiNX  Replace The Motor Replacement: Schritt 3, Bild 1 von 2 Hoover LiNX  Replace The Motor Replacement: Schritt 3, Bild 2 von 2
    • Remove the brush and retainer from the rolling assembly.

    • The brush will need to be disconnected from the belt.

  4. Hoover LiNX  Replace The Motor Replacement: Schritt 4, Bild 1 von 1
    • Remove the eight 4mm Phillips #1 screws from the bottom panel.

  5. Hoover LiNX  Replace The Motor Replacement: Schritt 5, Bild 1 von 1
    • Remove the bottom panel.

  6. Hoover LiNX  Replace The Motor Replacement: Schritt 6, Bild 1 von 1
    • Remove the motor.

Abschluss

To reassemble your device, follow these instructions in reverse order.

3 weitere Nutzer:innen haben diese Anleitung absolviert.

Sara Vlhova

Mitglied seit: 01/25/18

541 Reputation

4 Anleitungen geschrieben

Team

USF Tampa, Team S7-G4, Passmore Spring 2018 Mitglied von USF Tampa, Team S7-G4, Passmore Spring 2018

USFT-PASSMORE-S18S7G4

4 Mitglieder

12 Anleitungen geschrieben

3 Kommentare

Where does one get a new brush motor?

Brian - Antwort

Thank you for the photos! They’ve been helpful as I’m putting my Linx back together and can’t quite remember how the wires go back in the nozzle assembly. When putting the top plate back on, it’s a very tight fit where the top will be pushed up if maligned.

In the elbow part- It looks like the positive lead is on the left in your photo, but it would be helpful if you would add that specification to your step.

Great Job!

Paulie Jeanne - Antwort

In my case the (low quality) wires were broken and I had to just replace the wires from the motor to the contact points in the neck.

Paul Vale - Antwort

Kommentar hinzufügen