Zum Hauptinhalt wechseln

Nikon D70 CCD Board Replacement

Was du brauchst

  1. Nikon D70 CCD Board Replacement, Battery: Schritt 1, Bild 1 von 1
    • Use your finger tip to pull the battery release tab toward the center of the D70.

    • Open the battery door and rotate it away from the bottom cover.

  2. Nikon D70 CCD Board Replacement: Schritt 2, Bild 1 von 1
    • Pull the battery out of the D70.

    • It may be necessary to wiggle the battery while pulling to free it from its pocket in the case.

  3. Nikon D70 CCD Board Replacement, Bottom Cover: Schritt 3, Bild 1 von 1
    • Remove the following eight screws securing the bottom cover to the D70:

    • Six 5.8 mm Phillips screws

    • One 10.7 mm Phillips screws

    • One 8.2 mm Phillips screws

  4. Nikon D70 CCD Board Replacement: Schritt 4, Bild 1 von 2 Nikon D70 CCD Board Replacement: Schritt 4, Bild 2 von 2
    • Carefully pull the bottom cover to separate it from the body of the D70.

    • Remove the bottom cover from the D70.

  5. Nikon D70 CCD Board Replacement, Memory Compression Board: Schritt 5, Bild 1 von 3 Nikon D70 CCD Board Replacement, Memory Compression Board: Schritt 5, Bild 2 von 3 Nikon D70 CCD Board Replacement, Memory Compression Board: Schritt 5, Bild 3 von 3
    • Remove the four ZIF ribbon cables highlighted in red by using the following procedure:

    • Use your fingernail to flip up the ZIF cable retaining flap on each socket.

    • Be sure you are prying up the retaining flap, not the socket.

    • Pull the ribbon cable straight out of its socket.

  6. Nikon D70 CCD Board Replacement: Schritt 6, Bild 1 von 1
    • Carefully peel back the piece of tape covering the Compact Flash ribbon cable socket.

    • It is not necessary to completely remove this piece of tape.

  7. Nikon D70 CCD Board Replacement: Schritt 7, Bild 1 von 3 Nikon D70 CCD Board Replacement: Schritt 7, Bild 2 von 3 Nikon D70 CCD Board Replacement: Schritt 7, Bild 3 von 3
    • Use your fingernails to carefully pull the ZIF cable lock away from its socket.

    • Do not try to completely remove the ZIF cable lock. It will move about 1 mm and stop.

    • Use a pair of tweezers to pull the Compact Flash ribbon cable out of its socket.

  8. Nikon D70 CCD Board Replacement: Schritt 8, Bild 1 von 1
    • Be sure not to lose the small iron core around the DC-In ribbon cable.

  9. Nikon D70 CCD Board Replacement: Schritt 9, Bild 1 von 1
    • Remove the four 4.3 mm Phillips screws securing the memory compression board to the D70.

  10. Nikon D70 CCD Board Replacement: Schritt 10, Bild 1 von 1
    • Use a pair of tweezers to pull the USB connector bracket away from the edge of the memory compression board.

  11. Nikon D70 CCD Board Replacement: Schritt 11, Bild 1 von 2 Nikon D70 CCD Board Replacement: Schritt 11, Bild 2 von 2
    • Grab the memory compression board by its edges at the position shown in the first picture.

    • Pull the memory compression board straight up off the DC/DC board to avoid damaging the connector on the underside of the memory compression board.

  12. Nikon D70 CCD Board Replacement, CCD Board: Schritt 12, Bild 1 von 2 Nikon D70 CCD Board Replacement, CCD Board: Schritt 12, Bild 2 von 2
    • De-route the two leads routed over the connector boxed in yellow.

    • Use your thumbnails to push the connector out of its socket.

  13. Nikon D70 CCD Board Replacement: Schritt 13, Bild 1 von 1
    • Remove the two Phillips screws securing the grip side of the rear cover to the D70.

  14. Nikon D70 CCD Board Replacement: Schritt 14, Bild 1 von 1
    • Remove the two Phillips screws securing the DC-In side of the rear cover to the D70.

  15. Nikon D70 CCD Board Replacement: Schritt 15, Bild 1 von 2 Nikon D70 CCD Board Replacement: Schritt 15, Bild 2 von 2
    • Carefully pull the sides of the rear cover away from the body of the D70.

    • Pull the rear cover off the body of the D70, minding the LCD board ribbon cable that may get caught.

  16. Nikon D70 CCD Board Replacement: Schritt 16, Bild 1 von 1
    • At this point, the capacitor is visible and its exposed contacts are boxed in red. Even though they are recessed, be careful not to touch the contacts to avoid shocking yourself.

  17. Nikon D70 CCD Board Replacement: Schritt 17, Bild 1 von 1
    • Peel back the piece of tape connecting the iron core around the CCD board ribbon cable to the inner case.

  18. Nikon D70 CCD Board Replacement: Schritt 18, Bild 1 von 1
    • Remove the four 4.8 mm Phillips screws securing the CCD board to the D70.

  19. Nikon D70 CCD Board Replacement: Schritt 19, Bild 1 von 2 Nikon D70 CCD Board Replacement: Schritt 19, Bild 2 von 2
    • Remove the CCD board from the D70, minding any cables that may get caught.

    • When reinstalling the CCD board, be sure to press the alignment posts on the right and bottom edges of the board up against the guides machined into the case while tightening the screws down.

Abschluss

To reassemble your device, follow these instructions in reverse order.

25 weitere Nutzer:innen haben diese Anleitung absolviert.

2 Kommentare

Great instructions.

One important note: When re-installing the CCD board ribbon cable into the CCD board, the cable will go into the connector about 2mm and feel like it's seated. However, the cable must go 3mm-4mm into the connector. Otherwise, you will get a "This Card Cannot Be Used" error message each time you depress the shutter button.

Ross Edmond - Antwort

Great article.

davidmagen85 - Antwort

Kommentar hinzufügen