Was du brauchst

  1. Olympus VR-350 Lens Box Unit Replacement, Front Plate: Schritt 1, Bild 1 von 2 Olympus VR-350 Lens Box Unit Replacement, Front Plate: Schritt 1, Bild 2 von 2
    • Remove the two 4mm screws from each side of the camera with a Phillips PH000 screwdriver.

  2. Olympus VR-350 Lens Box Unit Replacement: Schritt 2, Bild 1 von 1
    • Remove the four 4mm screws from the bottom of the camera with a Phillips PH000 screwdriver.

  3. Olympus VR-350 Lens Box Unit Replacement: Schritt 3, Bild 1 von 3 Olympus VR-350 Lens Box Unit Replacement: Schritt 3, Bild 2 von 3 Olympus VR-350 Lens Box Unit Replacement: Schritt 3, Bild 3 von 3
    • Use the plastic opening tools and your fingers to pry the front plate from the camera.

    • You might need to open the battery cover to remove the front plate.

  4. Olympus VR-350 Lens Box Unit Replacement, Back Plate: Schritt 4, Bild 1 von 2 Olympus VR-350 Lens Box Unit Replacement, Back Plate: Schritt 4, Bild 2 von 2
    • Use your fingers to pry open the back cover.

    • When you remove the back of the camera, the button membrane might fall out. Don’t lose this sheet.

    • The LCD screen is connected to the body of the camera by an orange ribbon cable. Don’t pull this ribbon cable out.

  5. Olympus VR-350 Lens Box Unit Replacement, LCD Screen: Schritt 5, Bild 1 von 2 Olympus VR-350 Lens Box Unit Replacement, LCD Screen: Schritt 5, Bild 2 von 2
    • Using the Phillips PH000 screwdriver, remove the 4mm screw from the bottom left corner of the button plate located under the button membrane.

  6. Olympus VR-350 Lens Box Unit Replacement: Schritt 6, Bild 1 von 1
    • Pull the button pad up to fully reveal the visible ribbon cable.

    • You might need to bend the button pad out of the way.

  7. Olympus VR-350 Lens Box Unit Replacement: Schritt 7, Bild 1 von 1
    • Pull out the LCD screen and the ribbon cable.

    • The ribbon cable should be easy to pull out.

  8. Olympus VR-350 Lens Box Unit Replacement, Lens Box Unit: Schritt 8, Bild 1 von 1
    • Remove the metal plate that was underneath the LCD screen by removing the four 4 mm screws with the Phillips PH000 screwdriver.

  9. Olympus VR-350 Lens Box Unit Replacement: Schritt 9, Bild 1 von 2 Olympus VR-350 Lens Box Unit Replacement: Schritt 9, Bild 2 von 2
    • Remove the orange ribbon cable from the connector on the left side of the motherboard.

    • To do this, gently lift up the small grey clasp and pull the cable ribbon.

  10. Olympus VR-350 Lens Box Unit Replacement: Schritt 10, Bild 1 von 1
    • There are two other small ribbon cables under the motherboard connected to the lens box. Pull them out from the motherboard.

    • You may need to use force to pull out the ribbon cables.

  11. Olympus VR-350 Lens Box Unit Replacement: Schritt 11, Bild 1 von 1
    • Pull the lens box up and out to remove it.

Abschluss

To reassemble your device, follow these instructions in reverse order.

5 weitere Nutzer:innen haben diese Anleitung absolviert.

Brooke

Mitglied seit: 02/23/15

278 Reputation

1 Anleitung geschrieben

Team

USF Tampa, Team 1-3, Leahy Winter 2015 Mitglied von USF Tampa, Team 1-3, Leahy Winter 2015

USFT-LEAHY-W15S1G3

3 Mitglieder

10 Anleitungen geschrieben

Ein Kommentar

Worked for a SH-21, with a couple of extra screws to remove. Thank you!

Rick Allies - Antwort

Kommentar hinzufügen

Seitenaufrufe:

Letzte 24 Stunden: 0

Letzte 7 Tage: 2

Letzte 30 Tage: 11

Insgesamt: 1,484