Zum Hauptinhalt wechseln

Ryobi RJ1861V Saw Bar Assembly Replacement

Was du brauchst

  1. Ryobi RJ1861V Saw Bar Assembly Replacement, Saw Bar Assembly: Schritt 1, Bild 1 von 1
    • Use a Torx T5 screwdriver to remove the single 8 mm screw securing the shoe.

  2. Ryobi RJ1861V Saw Bar Assembly Replacement: Schritt 2, Bild 1 von 2 Ryobi RJ1861V Saw Bar Assembly Replacement: Schritt 2, Bild 2 von 2
    • Remove the rubber sleeve.

    • You may have to use some force as it has a tight fit.

  3. Ryobi RJ1861V Saw Bar Assembly Replacement: Schritt 3, Bild 1 von 1
    • Use a Torx T5 screwdriver to remove the six screws on the underside of the device.

  4. Ryobi RJ1861V Saw Bar Assembly Replacement: Schritt 4, Bild 1 von 1
    • Use a Torx T5 screwdriver to remove the four screws on the top of the gear case.

    • There are two screws on each side of the device.

  5. Ryobi RJ1861V Saw Bar Assembly Replacement: Schritt 5, Bild 1 von 1
    • Remove the backside panel.

  6. Ryobi RJ1861V Saw Bar Assembly Replacement: Schritt 6, Bild 1 von 1
    • Unscrew the four T5 Torx screws that hold the assembly bar in place.

  7. Ryobi RJ1861V Saw Bar Assembly Replacement: Schritt 7, Bild 1 von 1
    • Lift the assembly bar up and out of the chassis.

Abschluss

To reassemble your device, follow these instructions in reverse order.