Zum Hauptinhalt wechseln

Am 20. September 2019 hat Apple das neueste iPhone angekündigt. Der Nachfolger des iPhone XR hat ein 6,1 Zoll LCD-Touchscreen, ein neues Zwei-Kamera-System und ist in sechs verschiedenen Farben erhältlich.

473 Fragen Alle anzeigen

ThermalmonitorD error persists after replacing charging and power flex

I have replaced my charging port and the power/flashlight flex cable on my iPhone 11, however it still continues to reboot every three minutes. The error logs remain unchanged, continuing to state that thermalmonitord returned not alive.

Any ideas as to why thermalmonitord remains broken after the replacement of both flex cables?

Beantwortet! Antwort anzeigen Ich habe das gleiche Problem

Ist dies eine gute Frage?

Bewertung 1
Einen Kommentar hinzufügen

3 Antworten

Gewählte Lösung

If panic log shows mic1/PRS0 it's the port.

Mic 2 - power flex

Replacement has to be of high quality or a genuine pull, alot of replacements are sub-par. And also advise to test by plugging in the flex first before installing. As if you have a faulty one, it'll save you alot of time redoing all your work.

War diese Antwort hilfreich?

Bewertung 3

3 Kommentare:

I checked the panic log and it reported the missing sensor as prs0. I’d need an OEM charging port then?

von

@userc2 Yes. Jason at STS telecom has a pretty informative video on Youtube examining various charge port flexes under the microscope, specifically for iPhone 11 that I might recommend watching. (https://youtu.be/EIBHIhzRbI8) But an OEM pull will be your best bet.

von

@userc2 Has to be a genuine one, or high quality from a reputable seller who knows about how they work.

Alot of sellers just buy in bulk and not have a clue.

von

Einen Kommentar hinzufügen

You need to check exactly which sensor is not responding to thermalmonitord before deciding which one to replace.

War diese Antwort hilfreich?

Bewertung 1

5 Kommentare:

Hi, I am receiving error TR1D missing sensor. Any clue what it is?

von

@Vishal Patel I ran across a page in Japanese that seems to be about someone working on a program to read Apple sensors, and the TR1D sensor is listed like this:

sName:"PMU2 TR1d", sVal:37.5

PMU is, I believe, a Power Management Unit, but I'm not familiar enough with the logic board design to say what that means. Perhaps some of our more experienced contributors such as @flannelist can add to this. Here's the page I saw it on.

http://piyocast.com/as/archives/category...

von

@Vishal Patel Which device is it for? I have not ever seen TR1D, but I might be able to do some research with more info.

von

@Alisha C This Ipad 11 pro 2019 model.

von

@Vishal Patel iPad Pro 10.5" seems to have a TT1D in the display, I would wager the "D" at the end in your sensor also refers to display, but I cannot say for sure. iPad sensors are less well documented. Someday when I have a mountain of time, and mostly devices, I have designs on figuring that out. But for now I would think it could be something with the display or display cables.

von

Einen Kommentar hinzufügen

You can see your panic log data that will help to find your issues. Most of the aftermarket Flex is not working properly. So, Use original flex. How to find a panic log instruction to find the restart cause and the way were clearly shown and explained. This restart on 3 minutes faults is mostly common on X to up all models of iPhones.

War diese Antwort hilfreich?

Bewertung 0
Einen Kommentar hinzufügen

Antwort hinzufügen

Aydan wird auf ewig dankbar sein.
Seitenaufrufe:

Letzte 24 Stunden: 7

Letzte 7 Tage: 18

Letzte 30 Tage: 57

Insgesamt: 4,184