Wonky Pins

How to Service the Northbridge Heatsink

Single Processor Mac Pro 4,1 & 5,1?

Step by Step Instructions

Many people service their computers without using an anti-static mat. Usually this doesn't cause a problem. However, it takes only one spark of static electricity to destroy an entire computer. It is wiser to take precautions against this possibility. See what Steve Jobs had to say about SED.

The green & yellow cable (right) will be clipped to the central heating radiator, which is well grounded through the plumbing. The computer will be placed on the anti-static mat and doesn't need to be connected, but any components that have been removed from the computer and are being handled should be grounded with the black clip. The blue stretchy cable goes to the wrist connector.

Avoid working in a room with a carpet made from synthetic fibres, especially if you are wearing silicone rubber soled shoes. If you cannot avoid this, take your shoes off and make certain to wear the wrist connector while handling computer components.

!

The computer is placed on the anti-static pad and is grounded.

Place the lid on the edge of the anti-static pad. This will give you additional grounded area for putting things aside while you work.

I clear my table before starting work on any computer, to avoid the possibility of accidentally exchanging components or losing small items like screws.

!

The processor tray has been removed and is now grounded through the black cable. It will remain grounded as I pick it up and manipulate it.

!

The wrist cable is attached to my wrist. I am right handed, but had to do most of this left handed so that I could take the photographs with my right hand.

When connecting the wrist cable, wet your wrist (lick it) at the contact point to ensure good grounding.

If your ground is good, you do not need to worry about getting a shock. However, do not handle mains powered equipment while grounded like this. Battery powered drills and screwdrivers cannot give you a dangerous shock.

!

Remove the memory cards and place them on the computer lid.

Close the latches on the memory slots. If left open they can more easily be broken off accidentally.

!

Use a 3 mm hexagonal wrench to release the heatsink. The wrench must be at least 15 cm long. Release the holding bolts ONE TURN at a time, following an X pattern (top left, bottom right, top right, bottom left, far left) and continue until you hear a release click. Note: do not completely undo one bolt and then move to the next. Instead, repeat this patter, making one turn at a time, until the heatsink is released from the PCB.

When you replace the heatsink use the same pattern to tighten the bolts. Do not tighten more than finger tight. Make sure that the same tension is applied to each of the bolts. Uneven pressure can result in the CPU contacts failing. Symptoms range from boot-failure to missing or malfunctioning memory cards.

!

Dust acts like a blanket that keeps the PCB warm. The PCB and heatsinks, fans, case interior and so on should be cleaned regularly. Take this opportunity to clean the board.

Use an anti-static brush. Do not use any brush, for some cause static charge to build up and can damage the electronic components. Compressed air is also useful, especially for cleaning out the CPU heatsink.

!

Remove the nine screws holding the PCB to the tray.

Place the screws on the lid, in the well below the memory cards. This will prevent the screws from rolling away.

!

Remove the PCB and put it in a safe place where it is grounded. Here it is out of the way leaning on the computer.

You will discover dirt and grim on the tray under the PCB. Clean it with isopropanol using lint-free cloth.

Note the nine PCB screws on the lid.

!

You will be amazed at how much dust and gunk comes off the tray.

I use eye-glasses clearn pads to give the tray a finishing shine. The same lint-free wet-strength paper is suitable for other cleaning tasks on the Mac Pro. Place the tray on the