Schritt 6
  • In its resting state, the pressure sensor should be continuous, which means the meter should read almost zero resistance.

  • If the meter shows a high resistance or no continuity, it could mean that the sensor contacts are dirty. Double-check your meter contacts and make sure they're grasping onto the wires.

  • Use a spudger or your finger to firmly press on the top of the sensor until it clicks.

  • The meter should change to show no continuity (0.L, in my meter's case). If it doesn't, there is a potential electrical short—the contacts may be fused, or you may need to replace the sensor.

In questo stato di riposo, il sensore della pressione dovrebbe risultare continuo, il che significa che il multimetro dovrebbe leggere un resistenza quasi nulla.

Se il multimetro mostra una resistenza elevata o nessuna continuità, potrebbe significare che i contatti del sensore sono sporchi. Ricontrolla i contatti del multimetro ed assicurati che facciano contatto con i cavi.

Usa uno spudger o le tue dita per premere con decisione sul sensore finché non scatta.

Il multimetro dovrebbe mostrare nessuna continuità (0.L nel mio caso). Se non lo fa, c'è un potenziale corto circuito: i contatti potrebbero essere fusi, o potresti dover sostituire il sensore.