The Samsung NaviBot SR8855 is a handy autonomous vacuum by Samsung.

21 Fragen Alle anzeigen

Short shift and turn.

Navibot sr8855 after repair of FET tranzistors for brush have bad mooving - navigation.

From the beginning it worked well and after some time was problem in navigation.

It looks like that: move 20-30cm stop and go back about 3cm, turn 90st. and repeat.

Sometimes work good for 1 minute and then again fail to this state.

I try test mod and all sensors look fine, motors are OK too.

Diese Frage beantworten Ich habe das gleiche Problem

Ist dies eine gute Frage?

Bewertung 1

1 Kommentar:

I have the same issue. Is there a fix?

von

Einen Kommentar hinzufügen

5 Antworten

Hi,

yes, i found that it was dusturbation in system . I add some capacitors on motor and all is OK

War diese Antwort hilfreich?

Bewertung 0
Einen Kommentar hinzufügen

Can you describe more precise what did you done?

Could be the aging of the accumulator?

War diese Antwort hilfreich?

Bewertung 0
Einen Kommentar hinzufügen

I must replace suction motor and with it start the disturbance of electronics. For this I used capacitors on motor pads. I was 1nF + 100nF + 1uF together. To other motors must be carefull becouse are PWM drivered. There You can use only some smaller - max 100nF capacitors.

War diese Antwort hilfreich?

Bewertung 0

1 Kommentar:

Hi

What voltage do you use in capacitors?

von

Einen Kommentar hinzufügen

Can be that the battery started to decay?

War diese Antwort hilfreich?

Bewertung 0
Einen Kommentar hinzufügen

It could probably have an effect but it is not a reason.

War diese Antwort hilfreich?

Bewertung 0
Einen Kommentar hinzufügen