The compressor failed after little over 3 years

I have the same LG. The compressor failed after little over 3 years. 3 months after replacing the compressor, the fresh food is warm and but the freezer is around 0F. Since it is a dual evaporator system with single compressor, could it be the 3way check value that is switching between the evaporator?

Beantwortet! Antwort anzeigen Ich habe das gleiche Problem

Ist dies eine gute Frage?

Bewertung 0
1 Kommentar

Johan hay, have you looked at the fresh food evaporator? Is there any ice on it?

von

Einen Kommentar hinzufügen

1 Antwort

Gewählte Lösung

Johan hay, Yes it could be that 3 way valve. Most cycle from one evaporator to the other every 15 minutes +-

War diese Antwort hilfreich?

Bewertung 3