Zum Hauptinhalt wechseln

This receiver is Bluetooth Ready, has 110 Watts x 5 Direct Energy Amplification and is iPad / iPhone Certified with supplied cable

26 Fragen Alle anzeigen

The device switches off after the second relais click

Hi,

I have a VSX-922 but I assume this doesn't make a big difference.

The received worked fine for years but recently just shut off during normal use. If I now try to turn it on, the device powers up, the display shows "STEREO", and I can hear the first relais click. But immediately after the second relais click the device shuts off and the iPod LED starts blinking.

Any ideas what might be wrong with it?

Diese Frage beantworten Ich habe das gleiche Problem

Ist dies eine gute Frage?

Bewertung 0
Einen Kommentar hinzufügen

1 Antwort

According to the service manual, this is an indication of either "AMP overload" or "abnormal DC voltage in the power supply". I would expect that the problem is in the AMP section as this is the most common failure. Since this unit uses discrete transistors as outputs, I expect to find at least one that is shorted which would cause the symptom you describe. If you are comfortable working on these, finding and changing the outputs should be relatively easy. Always change them in pairs. This is because when one fails it places extreme stress on the other one in the pair.

Hope this helps,

Dan

War diese Antwort hilfreich?

Bewertung 0
Einen Kommentar hinzufügen