Zum Hauptinhalt wechseln

Popular clothes dryer series by Kenmore.

60 Fragen Alle anzeigen

Can a blown Cutoff fuse keep my dryer from starting

Changed thermal fuse and fixed heater coil that was grounded. It blew the timer which I also fixed and have Continuity everywhere except the cutoff fuse. It still won’t start. Is this why are is it Control panel issues?

Update (09/29/2020)

Roper mod# red4640YQ1

Beantwortet! Antwort anzeigen Ich habe das gleiche Problem

Ist dies eine gute Frage?

Bewertung 0
4 Kommentare

It’s an older Roper model

von

I’ll get a better description if you need when I get off this afternoon

von

Thank you I really appreciate it!!

von

Update: the fuse was changed and dryer is running.... but now it just starts before pressing the start switch!!! Any suggestions?

von

Einen Kommentar hinzufügen

1 Antwort

Gewählte Lösung

What exact model is this? We need to know that in order to try and look at the schematic and yes a bad cutoff can be the issue, but there may be more going on here.

Update (10/01/2020)

Ben Lewis, I can confirm that if the fuse is bad the dryer won't start or will run but not heat. So I would suggest to start with the fuse.

War diese Antwort hilfreich?

Bewertung 1

1 Kommentar:

I posted in the old comments didn’t know if you would see it but the fuse worked but now when I put it on a cycle it just starts up before pressing start switch

von

Einen Kommentar hinzufügen

Antwort hinzufügen

Ben Lewis wird auf ewig dankbar sein.
Seitenaufrufe:

Letzte 24 Stunden: 1

Letzte 7 Tage: 1

Letzte 30 Tage: 4

Insgesamt: 103