Haptic and charging and rebooting

1, I just changed the housing in my iPhone 11 first time, now when I was taking the the flash and back microphone out I snapped the ribbon cable just before the micro phone part, will this have and issues with it rebooting. 2, haptic engine and charging port is now working the ribbon cable seem to not be clicking into tho logic board phone restarts after a few minutes use,

Any tips or info be great thanks

Update phone working fine now my 4g is showing and I can receive phone calls but not access the internet sim try looks to be sitting in the phone a little bit

Block Image

Beantwortet! Antwort anzeigen Ich habe das gleiche Problem

Ist dies eine gute Frage?

Bewertung 1
Einen Kommentar hinzufügen

2 Antworten

Gewählte Lösung

Most iPhones have a sensor on the power/flash flex called the mic2 sensor that will cause the phone to boot loop in three minute intervals if that sensor fails. I figure once you get into the panic logs, there's probably about a 90% chance you'll see a line saying something like, "missing sensor: mic2". Once you replace that cable, that should fix your boot loop issue.

Alisha (@flannelist) has written our definitive guide to kernel panics and it's definitely worth a look.

iPhone Kernel Panics - iFixit

Assuming you are on a three minute reboot cycle, that's actually long enough to get in and catch a screenshot of the first page of the panic log, which is really all we need to verify the cause.

War diese Antwort hilfreich?

Bewertung 3

2 Kommentare:

I have no access to pc atm will do next few days will swap the part tomorrow and let you know thanks for the info

von

@sebastianfurber Actually, if your phone boots normally for that first three minutes, you can access the logs without a PC. Instructions are in the Wiki page I linked to.

von

Einen Kommentar hinzufügen
Hilfreichste Antwort

If you had to transfer the charge port over, it can be a little tricky aligning the flex cable connector. Rebooting can be caused by a few things, a faulty or aftermarket charge port, or a damaged power or volume flex cable. If you can get it to connect to a computer, you can use this video to read the panic log to help pinpoint the cause of the problem: https://www.youtube.com/watch?v=QaJLYbtu...

War diese Antwort hilfreich?

Bewertung 3

1 Kommentar:

Fixed the charging port all original parts, I’v a new power button flex cable coming to replace the ones that snapped at microphone/flash part hoping that will do and will look into using a pc to get the panic log many thanks

von

Einen Kommentar hinzufügen