Schritt 8
Philips Norelco BG2040/34 BodyGroom 7100 Battery Replacement, Remove Batteries: Schritt 0, Bild 1 von 3 Philips Norelco BG2040/34 BodyGroom 7100 Battery Replacement, Remove Batteries: Schritt 0, Bild 2 von 3 Philips Norelco BG2040/34 BodyGroom 7100 Battery Replacement, Remove Batteries: Schritt 0, Bild 3 von 3
Remove Batteries
  • This part requires skill and care.

  • Using needle nose pliers, pry off the wires and metal tabs carefully.

  • Be careful to not damage the metal tabs/connectors! They will be reused.

  • If you're having trouble prying off the wires, you may try drilling out the welds that secure the wires. Note that it's easy to permanently damage components when drilling, so only attempt this procedure if you're confident.

Dieser Schritt erfordert besonderes Geschick.

Löse die Kabel und Metalllaschen behutsam mit einer Spitzzange ab.

Achte darauf, dass die Metalllaschen/Kontakte nicht beschädigt werden, du brauchst sie später noch.

Wenn die Kabel nicht leicht abgehen, dann müssen vielleicht die Lötstellen, an denen sie befestigt sind, abgebohrt werden. Beachte, dass die Gefahr, etwas zu beschädigen, beim Bohren groß ist, mache das nur, wenn du dich sicher fühlst.