Prerequisite guide only! Removes the handle from the body of the Rug Doctor.

Werkzeuge

Ersatzteile

Keine Ersatzteile angegeben.

  1. Before you begin disassembly, make sure that the Rug Doctor is not plugged in and that all reservoirs are empty of liquids.
    • Before you begin disassembly, make sure that the Rug Doctor is not plugged in and that all reservoirs are empty of liquids.

    • Unclip the clear hose from the back of the Rug Doctor.

  2. Use a 7/16" (11 mm OK) wrench to hold the handle axle while you use a 7/16" socket to remove the cap nut securing the axle end. Use a 7/16" (11 mm OK) wrench to hold the handle axle while you use a 7/16" socket to remove the cap nut securing the axle end.
    • Use a 7/16" (11 mm OK) wrench to hold the handle axle while you use a 7/16" socket to remove the cap nut securing the axle end.

  3. Support the handle with one hand. It will be loose after this step. Use fingers or pliers to pull out the handle axle.
    • Support the handle with one hand. It will be loose after this step.

    • Use fingers or pliers to pull out the handle axle.

    • If the axle feels hard to pull out, squeeze the handle release lever to release pressure on the axle.

  4. Detach the handle from the Rug Doctor and set it down.
    • Detach the handle from the Rug Doctor and set it down.

    • If you need more cable slack, you can set the Rug Doctor on its side.

Abschluss

To reassemble your device, follow these instructions in reverse order.