Zum Hauptinhalt wechseln

Support and repair information for Marantz home theater AV receivers and older audio-only receivers.

46 Fragen Alle anzeigen

Electrical hissing from on knob.

I have a vintage Marantz 2220B receiver. There is a hissing sound coming form the on/off knob. The sound last for about four minuets and stops. I produces sound for the unit the display panel light dim for time to time.

Beantwortet! Antwort anzeigen Ich habe das gleiche Problem

Ist dies eine gute Frage?

Bewertung 0
Einen Kommentar hinzufügen

1 Antwort

Gewählte Lösung

brn, Unplug receiver, take the cabinet/cover off component to access switch, check to ensure switch has good connections, spray switch liberally with electro contact cleaner while working switch. Check connections for the lights while apart also. Good Luck.

I hope this helped you out, if so let me know by pressing the helpful button.

War diese Antwort hilfreich?

Bewertung 1

1 Kommentar:

The hissing, may be high voltage arcing. Being a power switch, it has 117VAC through it, to the rest of the amplifier. Switches are normally on, or off. So they do not normally dissipate any heat. But the old contacts are not making a good connection, so the contacts have a very high resistance. This will cause them to overheat. You may find that the switch has melted, and may need to be replaced. Probably not, but could be a fire hazard. I would "consider" trying to find a replacement.

von

Einen Kommentar hinzufügen

Antwort hinzufügen

brnmacfarlane wird auf ewig dankbar sein.