Changed 4-prong to 3-prong after a move.

Kenmore Elite He3 powers on, but will not work. Tested the electricity from outlet and wires (by a retired electrician). He says all work. He advised calling an appliance person to test motherboard, circuits. Each person I telephoned has never heard of a motherboard, circuit board. Please help.

Kismet

Beantwortet! Antwort anzeigen Ich habe das gleiche Problem

Ist dies eine gute Frage?

Bewertung 0
2 Kommentare

They would just call it a different name, like control board or something similar. This pdf should help with the diagnosis. Kenmore-Elite-HE3-Dryer-Tech-Sheet.pdf

von

@kismet post some images of your outlet, the plug and how it is wired into the machine. Use this guide Bilder zu einer vorhandenen Frage hinzufügen for that It will allow us to see what you see.

von

Einen Kommentar hinzufügen

1 Antwort

Gewählte Lösung

The 4 prong power cord had the ground (green) wire screwed to the cabinet and the 3 other wires were screwed to the terminal block. A 3 prong power cord doesn’t have a ground (green) wire. The middle terminal on the block has a white (neutral) wire that needs to be screwed to the cabinet where the ground (green) wire was attached. This is a common mistake.