Safety

This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further information.

Image

△

This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages may be present

Image

□

Double insulation

  1. Improper use of this meter can cause damage, shock, injury or death. Read and understand this user manual before operating the meter.

  2. Make sure any covers or battery doors are properly closed and ured.

  3. Always remove the test leads before replacing the battery or fuses.

  4. Inspect the condition of the test leads and the meter itself for any damage before operating the meter. Repair any damage before use.

  5. Do not exceed the maximum rated input limits.

  6. Use great care when making measurements if the voltages are greater than 25VAC rms or 35VDC. These voltages are considered a shock hazard.

  7. Always discharge capacitors and remove power from the device under test before performing Diode, Resistance or Continuity tests.

  8. Remove the battery from the meter if the meter is to be stored for long periods.

  9. To avoid electric shock, do not measure AC current on any circuit whose voltage exceeds 250V AC.

Input Limits
FunctionMaximum Input
VDC, VAC600V AC/600V AC
Resistance, Diode, Continuity500V DC/AC
mA DC200mA DC
10A DC10A DC (15 seconds max. every 15 min.)
Frequency250V DC/AC

Warranty

EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment (a six month limited warranty applies on sensors and cables). If it should become necessary to return the instrument for service during or beyond the warranty period, contact the Customer Service Department at (781) 890-7440 ext. 210 for authorization or visit our website at www.extech.com for contact information. A Return Authorization (RA) number must be issued before any product is returned to Extech. The sender is responsible for shipping charges, freight, insurance and proper packaging to prevent damage in transit. This warranty does not apply to defects resulting from action of the user such as misuse, improper wiring, operation outside of specification, improper maintenance or repair, or unauthorized modification. Extech specifically disclaims any implied warranties or merchantability or fitness for a specific purpose and will not be liable for any direct, indirect, incidental or consequential damages. Extech's total liability is limited to repair or replacement of the product. The warranty set forth above is inclusive and no other warranty, whether written or oral, is expressed or implied.

User's Manual

EXTECH INSTRUMENTS

MiniTec™ Series Model MN36 Auto-Ranging Mini MultiMeter

Image

3999

Introduction

Congratulations on your purchase of Extech's MN36 Auto-Ranging Multimeter. This meter measures AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Frequency, Temperature, Diode Test and Continuity. Proper use and care of this meter will provide many years of reliable service.

Specifications

AccuracyStated at $ 73°F \pm 10°F $ ( $ 23°C \pm 5°C $) and less than 70% RH
Diode TestTest current of 0.6mA maximum, open circuit voltage 1.5V DC typical
Continuity CheckAudible signal will sound if the resistance is less than approximately

Specifications

FunctionRangeAccuracy
DC Voltage (V DC)400.0mV$ \pm $(0.5% reading + 4 digits)
4.000V$ \pm $(0.8% reading + 4 digits)
40.00V
400.0V
600V
AC Voltage (V AC)50-60Hz40-400Hz
4.000V$ \pm $(0.8% rdg + 4 d)$ \pm $(2% rdg + 5 d)
40.00V$ \pm $(1.2% rdg + 5 d)
400.0V
600V
DC Current400.0 $ \mu $A$ \pm $(1.2% reading + 4 digits)
4000 $ \mu $A
40.00mA
200.0mA
10A$ \pm $(2.5% reading + 4 digits)
AC Current (40 to 400Hz)400.0 $ \mu $A$ \pm $(1.5% reading + 5 digits)
4000 $ \mu $A
40.00mA
200.0mA
10A$ \pm $(3% reading + 5 digits)
Resistance400.0 \Omega$ \pm $ (1.2% reading + 4 digits)
4.000k \Omega
40.00k \Omega
400.0k \Omega
4.000M \Omega
20.00M \Omega$ \pm $ (3.0% reading + 5 digits)
Capacitance4.000nFNot specified
40.00nF$ \pm $ (3.0% reading + 10 digits)
400.0nF
4.000 \mu F
40.00 \mu FNot Specified
100 \mu F
Frequency10.00Hz$ \pm $ (1.0% reading + 4 digits) 10Hz to 1MHz
100Hz
1.000kHz
10.00kHz
100.0kHzSensitivity: 5.0Vrms
1.000MHz
5.000MHzNot specified
Temp °F-40 to 1400°F-40 to 650°F; $ \pm $ (1.0% rdg + 10 digits) 651 to 1400°F; $ \pm $ (3% rdg + 10 digits) -20 to 400°C; $ \pm $ (1.0% rdg + 10 digits) 400 to 750°C; $ \pm $ (3% rdg + 10 digits) (probe accuracy not included)
Temp °C-20 to 750°C

Symbols

Meter Description

  1. LCD Display

  2. DATA HOLD button

  3. SELECT button

Melde dich kostenlos bei iFixit an, um die vollständige Anleitung zu lesen (2 Seiten)

Wir benötigen ein kostenloses Konto, um Bots zu blockieren und iFixit für Menschen zu erhalten.

Seitenaufrufe:

Letzte 24 Stunden: 9

Letzte 7 Tage: 10

Letzte 30 Tage: 10

Insgesamt: 10