Escort 1000 2000 Service Manual.pdf

102 Seiten · 6.55 MB · PDF

ESCORT

SERVICE MANUAL

1000/2000

MEDICAL DATA ELECTRONICS

12720 WENTWORTH STREET ARLETA, CA 91331 (818) 768-6411 (800) 237-5243 FAX (818) 788-0759

  • 6.0

ESCORT 1 000/2000 OPERATOR ' S MANUAL TABLE OF CONTENTS

1.0 introduction

  • 1.1 DISTINCTIVE FEATURES
  • 1.2 SYSTEM CONFIGURATIONS AND opTiONS
  • 1.3 SAFETY CONSIDERATIONS
  • 2.0 CONTROLS AND INDICATORS
  • 2.1 FRONT PANEL
  • 2.2 REAR PANEL
  • 3.0 DISPLAY FORMAT AND SYSTEM MESSAGES
  • 4.0 ESCORT PREPARATION
  • 4.1 BATTERY AND AC POWER OPERATION
  • 4.2 ESCORT TuRN-ON AND SETUP PROCEDURE
  • 4.3 ELECTRODE PLACEMENT
  • 4.4 TELEMETRY TRANSMITTER
  • 4.5

5.0 SUPPLEIENTARY PROCEDURES

  • 5.1 SQFT KEY PAGING
  • 5.2 HELP KEY
  • 5.3 RECORDER
  • 5.4 SELECTING TELEMETRY CHANNELS
  • 5.5 TRENDING HEART RATE
  • 5.6 ELAPSED TIMER
  • 6.1 SELF TEST
  • 6.2 TROUBLEshOOTING GUIDE
  1. 0 CARE ANC CLEANING

ILLUSTRATIONS

DESCRIPTIONSECTION NUMBERILLuSTRATION NUMBER
TRANSMITTER FEATURE TABLE1.2TABLE
PANEL2.1FIGURE
REAR PANEL CONTROLS2.2FIGURE 2
SINGLE PATIENT DISPLAY FORMAT (ESCORT 1000)3.0FIGURE 3A
DUAL PATIENT DISPLAY FORMAT3.0FIGURE 3B
DISPLAY FORMAT In HELP MODE3.0FIGURE 3C
START UP DEF AULT conditionS4.5TABLE 2
HOME SOFTKEY PAGE5.1FIGURE 4
ESCORT SOFTKEY PAGES5.1FIGURE 5A
ESCORT 2000 SOFTKEY PAGES5.1FIGURE SB
RECORDER PAPER INSTALLATION5.3FIGURE 6
RECORDING OF FROZEN ECG5.3FIGURE 7
TELEMETRY CHANNEL SELECT SOF TKEYS (ESCORT5.4FIGURE 8A
TELEMETRY CHANNEL SELECT SOF TKEYS (ESCORT 15.4FIGURE 8B
TELEMETRY CHANNEL STOP SOF TKEY PAGE5.4FIGURE 9
TREND SOFTKEY PAGE5.5FIGURE 10
TREND RECORDING5.5FIGURE 11
ELAPSED TIME DISPLAY5.6FIGURE 12

Table Caption: This table categorizes various features, controls, and operational aspects of a transmitter, linking their descriptions to specific section and illustration numbers. It serves as a navigational aid for understanding the transmitter's components and functionalities.

1.0 introduction

1.1 DISTINCTIVE FEATURES

EscORT has many distinctive features but three features are particularly unique:

ESCORT can be igured at the factory to Work With almost any type ECG telemetry transmitter available today _ Consequently ESCORT can usually be configured to Work With your existing transmitters_ conf_

  • EscORT has a multi channel receiver that permits YOU to select and monitor any one (EscORT 1000) any (EscoRT 2000) of up to 360 telemetry patients_ The number of patients that the ESCORT can select varies With the type of transmitter used _
  • ESCORT is very compact a includes an option for battery power operation Which permits portable applications_

The ESCORT is a dual trace single channel ECG monitor Which receives ECG via telemetry. The EscoRT 2000 is a dual trace, dual channel, telemetry ECG monitor. The two models operate similarly _ The major difference between the models is that the ESCORT 1 000 monitors one patient at a time and the ESCORT 2000 monitors two patients simultaneously.

The ESCORT 000/2000 is designed to minimize the number of functions which confront the user at any one time_ Some keys (fixed function keys) are visible and functioninq at all times. Other less frequently used functions are visible and functioning only on an as needed basis_ The four variable function keys are called "softkeys" The four softkeys are located immediately below the display Labels for the four softkeys are displayed on the screen Softkey labels are located above each respective soft key key key .

1.2 SYSTEM ConfiguRATIONS AND OPTIONS

The ESCORT 1000 (single patient) and the ESCORT 2000 (dual patient) can be configured at the factory to receive telemetry ECG from almost any telemetry transmitter currently available_ Some monitoring features may Or may not be provided depending upon the capabilities and transmission techniques of the transmitter _ Low battery, lead fail, remote record; and cal are all features With signals that normally originate at the transmitter_ See TABLE 1 to determine feature compatibility between ESCORT and the various transmitters_

TABLE TRANSMITTER FEATURE TABLE YES: SIGNAL SUPPORTED)

TRANSMITTERLOWREMOTELEADCAL
BATRECORDFAIL
ABBOTT TR4NONONONO
ANTEKNONONONO
BURDICK/KONEYESYESNOYES
DATASCOPEYESYESNOYES
EforM/HONEYWELL Tt31YESYESYES
GE PDS 3020YESYESNONO
3100NONONONO
HP 78100NONOYESNO
TLTYESYESNOYES
LSE /QuitonNOnONONO
MARCOM/PHYSIO/MADNONONO
MARQUETTE 9416NONONO
MDE ESCORT 1100YESYESYES
MENNEN 419YESNONOYES
nIHON KOHDEN 311NONONoNO
KOHDEN 632/654NO
SIEMENS 400YESYESNoYES
SPACELABS 200NONONO
SPACELABS 300YESNONONO
SPACELABS 310YESYESNONO

Table Caption: This table lists various transmitters and indicates which signals (LOW BAT, REMOTE RECORD, LEAD FAIL, CAL) they support with a "YES" or "NO".

In many applications the ESCORT 1000/2000 Will be used to receive ECG signals from the customer S existing transmitters For example, the ESCORT 1 000/2000 can be brought to a telemetry patient bedside to monitor the patient in parallel With the hospital' s primary monitoring system located at the central station_ In this situation ESCORT provides bedside monitoring With no need for additional patient cables electrodes_

1.3 SAFETY CONSIDERATIONS

When operating ESCORT from an AC power source, the wall receptacle must be a three-Wire, grounded, hospital grade outlet. Since the ESCORT 1000/2000 is telemetry monitor, all patient contact is via the battery powered transmitter _ Consequently , patient isolation is guaranteed_ If the ESCORT 000/2000 is used in the presence of flammable anesthetics a possible explosion hazard exists_ Never remove ESCORT's enclosure panels since dangerous high voltage Would be exposed. Always refer servicing to qualified personnel _

2.0 CONTROLS AND INDICATORS

2.1 FRONT PANEL

The function of each of the four soft keys is defined by the label displayed above the soft The "soft keys" are the four (4) green arrOW keys below the CRT screen_ Press to activate_ The soft label Will blank momentarily to echo depression. key key key

Help

When you presS this ESCORT responds With the following message:

FOR HELP. SELECT KEY

At this time press