Diese Person hat ihr Profil noch nicht ausgefüllt.
Anleitungs-Kommentare
A common problem with appliances that use transformerless power supplies is a shorted Zener diode, typically 12V 1W. This Zener regulates the supply for the IC(s).
I would think that the usual problem would be the conductive rubber keypad or the PCB contacts. Cleaning these with a cotton bud dipped in isopropyl alcohol should fix it.