To open that device you need a normal cross screwdriver and for one srew you need a torx srewdriver with torx 10.
=== Update (28.01.2017) ===
To repair the p1 error you have to replace the Hydro-Stat-Modul.
I do that and it works fine for me. Also you could only replace the hydro sensor on the old plate.
-
The new hydro-stat-modul had a short cable so I had to cut a new passway.
+
If you only want to replace the hydro sensor it would costs only 8,93€ + shipping costs
-
If you only want to replace the hydro sensor it would costs only 8,93€ + shipping costs
Why have I do that because my warranty had come to an end for one year so - I don't want to repair his device from the producer for a lot of money etc. and because it's fun to repair something yourself.
To open that device you need a normal cross screwdriver and for one srew you need a torx srewdriver with torx 10.
=== Update (28.01.2017) ===
To repair the p1 error you have to replace the Hydro-Stat-Modul.
I do that and it works fine for me. Also you could only replace the hydro sensor on the old plate.
The new hydro-stat-modul had a short cable so I had to cut a new passway.
-
For me it has cost only 10,16€. And if I want only to replace the hydro sensor it would only costs 8,93€ for me. Why have I do that because my warranty had come to an end for one year so - I don't want to repair his device from the producer for a lot of money.
+
If you only want to replace the hydro sensor it would costs only 8,93€ + shipping costs
+
Why have I do that because my warranty had come to an end for one year so - I don't want to repair his device from the producer for a lot of money etc. and because it's fun to repair something yourself.
To open that device you need a normal cross screwdriver and for one srew you need a torx srewdriver with torx 10.
=== Update (28.01.2017) ===
To repair the p1 error you have to replace the Hydro-Stat-Modul.
I do that and it works fine for me. Also you could only replace the hydro sensor on the old plate.
The new hydro-stat-modul had a short cable so I had to cut a new passway.
-
Same goes for the new cable ties: [https://lvdc4w-bn1305.files.1drv.com/y3pbcltp9h7He2cu2zSOX-Vvd1nu7-ZEQnId3oRfySIPYw5RGCdyzsXuCwn1wMUjCNKFdMz8TkRX3ueRj1eLRr0dxBfie7LVHhHtrbP1QUfoOaoPojJbrGKsLLYz87kIWdwO6-Wiv8ePQZoQYvKcKfJWx7hIoIngWnx_vyy1SJTdD0/WP_20170128_11_11_21_Rich.jpg?psid=1|Look here]
-
For me it has cost only 10,16€. And if I want only to replace the hydro sensor it would only costs 8,93€ for me. Why have I do that because my warranty had come to an end for one year so - I don't want to repair his device from the producer for a lot of money.
To open that device you need a normal cross screwdriver and for one srew you need a torx srewdriver with torx 10.
=== Update (28.01.2017) ===
To repair the p1 error you have to replace the Hydro-Stat-Modul.
-
I do that - look here ([https://z1xuqg-bn1305.files.1drv.com/y3pxesuoFkecFGQmNFubjE4FCwlJouF9EGNXVyIP-dm-cRh3J6pc1f_GgRJXrYUAsjusMTW8Oi2pfUR6PmC_JhI1q96I_bepgGqEwMw4jRwVnl0VlwJvAwLM5ieT86CF94Pm0X5HsSxXCVitrCkD3qa_W0hmX6oI8Dxp11E0XbmdLw/WP_20170128_11_11_10_Rich.jpg?psid=1|Picture Link]) and it works fine for me. Also you could only replace the hydro sensor on the old plate.
+
I do that and it works fine for me. Also you could only replace the hydro sensor on the old plate.
-
The new hydro-stat-modul had a short cable so I had to cut a new passway. Look [https://lvdc4w-bn1305.files.1drv.com/y3p7gs70O8Js0ObF5lBYbdpuaL9vnb4gLG7XV5pBluJK3VLSDrZ6TGdMbIljbMrRZQvmqfCdEY-uj6WIDxD5_D8GWY3WEdap5E6OGxW0mJekKlycHGHiEDxKM24VKm9KHnNfM9j5wmo_rqOm0V6b0NjYHMpZ0ZalmEePxMJvoGopdI/WP_20170128_11_11_37_Rich.jpg?psid=1|here].
+
The new hydro-stat-modul had a short cable so I had to cut a new passway.
Same goes for the new cable ties: [https://lvdc4w-bn1305.files.1drv.com/y3pbcltp9h7He2cu2zSOX-Vvd1nu7-ZEQnId3oRfySIPYw5RGCdyzsXuCwn1wMUjCNKFdMz8TkRX3ueRj1eLRr0dxBfie7LVHhHtrbP1QUfoOaoPojJbrGKsLLYz87kIWdwO6-Wiv8ePQZoQYvKcKfJWx7hIoIngWnx_vyy1SJTdD0/WP_20170128_11_11_21_Rich.jpg?psid=1|Look here]
For me it has cost only 10,16€. And if I want only to replace the hydro sensor it would only costs 8,93€ for me. Why have I do that because my warranty had come to an end for one year so - I don't want to repair his device from the producer for a lot of money.
To open that device you need a normal cross screwdriver and for one srew you need a torx srewdriver with torx 10.
=== Update (28.01.2017) ===
To repair the p1 error you have to replace the Hydro-Stat-Modul.
I do that - look here ([https://z1xuqg-bn1305.files.1drv.com/y3pxesuoFkecFGQmNFubjE4FCwlJouF9EGNXVyIP-dm-cRh3J6pc1f_GgRJXrYUAsjusMTW8Oi2pfUR6PmC_JhI1q96I_bepgGqEwMw4jRwVnl0VlwJvAwLM5ieT86CF94Pm0X5HsSxXCVitrCkD3qa_W0hmX6oI8Dxp11E0XbmdLw/WP_20170128_11_11_10_Rich.jpg?psid=1|Picture Link]) and it works fine for me. Also you could only replace the hydro sensor on the old plate.
The new hydro-stat-modul had a short cable so I had to cut a new passway. Look [https://lvdc4w-bn1305.files.1drv.com/y3p7gs70O8Js0ObF5lBYbdpuaL9vnb4gLG7XV5pBluJK3VLSDrZ6TGdMbIljbMrRZQvmqfCdEY-uj6WIDxD5_D8GWY3WEdap5E6OGxW0mJekKlycHGHiEDxKM24VKm9KHnNfM9j5wmo_rqOm0V6b0NjYHMpZ0ZalmEePxMJvoGopdI/WP_20170128_11_11_37_Rich.jpg?psid=1|here].
Same goes for the new cable ties: [https://lvdc4w-bn1305.files.1drv.com/y3pbcltp9h7He2cu2zSOX-Vvd1nu7-ZEQnId3oRfySIPYw5RGCdyzsXuCwn1wMUjCNKFdMz8TkRX3ueRj1eLRr0dxBfie7LVHhHtrbP1QUfoOaoPojJbrGKsLLYz87kIWdwO6-Wiv8ePQZoQYvKcKfJWx7hIoIngWnx_vyy1SJTdD0/WP_20170128_11_11_21_Rich.jpg?psid=1|Look here]
-
For me it has cost only 10,16€. And if I wanted only to replace the hydro sensor would only cost 8,93€ for me. Why have I do that because my warranty has come to an end for one year so I don't want to repair his device from the producer for a lot of money.
+
For me it has cost only 10,16€. And if I want only to replace the hydro sensor it would only costs 8,93€ for me. Why have I do that because my warranty had come to an end for one year so - I don't want to repair his device from the producer for a lot of money.
To open that device you need a normal cross screwdriver and for one srew you need a torx srewdriver with torx 15.
+
To open that device you need a normal cross screwdriver and for one srew you need a torx srewdriver with torx 10.
=== Update (28.01.2017) ===
To repair the p1 error you have to replace the Hydro-Stat-Modul.
I do that - look here ([https://z1xuqg-bn1305.files.1drv.com/y3pxesuoFkecFGQmNFubjE4FCwlJouF9EGNXVyIP-dm-cRh3J6pc1f_GgRJXrYUAsjusMTW8Oi2pfUR6PmC_JhI1q96I_bepgGqEwMw4jRwVnl0VlwJvAwLM5ieT86CF94Pm0X5HsSxXCVitrCkD3qa_W0hmX6oI8Dxp11E0XbmdLw/WP_20170128_11_11_10_Rich.jpg?psid=1|Picture Link]) and it works fine for me. Also you could only replace the hydro sensor on the old plate.
The new hydro-stat-modul had a short cable so I had to cut a new passway. Look [https://lvdc4w-bn1305.files.1drv.com/y3p7gs70O8Js0ObF5lBYbdpuaL9vnb4gLG7XV5pBluJK3VLSDrZ6TGdMbIljbMrRZQvmqfCdEY-uj6WIDxD5_D8GWY3WEdap5E6OGxW0mJekKlycHGHiEDxKM24VKm9KHnNfM9j5wmo_rqOm0V6b0NjYHMpZ0ZalmEePxMJvoGopdI/WP_20170128_11_11_37_Rich.jpg?psid=1|here].
Same goes for the new cable ties: [https://lvdc4w-bn1305.files.1drv.com/y3pbcltp9h7He2cu2zSOX-Vvd1nu7-ZEQnId3oRfySIPYw5RGCdyzsXuCwn1wMUjCNKFdMz8TkRX3ueRj1eLRr0dxBfie7LVHhHtrbP1QUfoOaoPojJbrGKsLLYz87kIWdwO6-Wiv8ePQZoQYvKcKfJWx7hIoIngWnx_vyy1SJTdD0/WP_20170128_11_11_21_Rich.jpg?psid=1|Look here]
For me it has cost only 10,16€. And if I wanted only to replace the hydro sensor would only cost 8,93€ for me. Why have I do that because my warranty has come to an end for one year so I don't want to repair his device from the producer for a lot of money.
To open that device you need a normal cross screwdriver and for one srew you need a torx srewdriver with torx 10.
+
To open that device you need a normal cross screwdriver and for one srew you need a torx srewdriver with torx 15.
=== Update (28.01.2017) ===
To repair the p1 error you have to replace the Hydro-Stat-Modul.
I do that - look here ([https://z1xuqg-bn1305.files.1drv.com/y3pxesuoFkecFGQmNFubjE4FCwlJouF9EGNXVyIP-dm-cRh3J6pc1f_GgRJXrYUAsjusMTW8Oi2pfUR6PmC_JhI1q96I_bepgGqEwMw4jRwVnl0VlwJvAwLM5ieT86CF94Pm0X5HsSxXCVitrCkD3qa_W0hmX6oI8Dxp11E0XbmdLw/WP_20170128_11_11_10_Rich.jpg?psid=1|Picture Link]) and it works fine for me. Also you could only replace the hydro sensor on the old plate.
The new hydro-stat-modul had a short cable so I had to cut a new passway. Look [https://lvdc4w-bn1305.files.1drv.com/y3p7gs70O8Js0ObF5lBYbdpuaL9vnb4gLG7XV5pBluJK3VLSDrZ6TGdMbIljbMrRZQvmqfCdEY-uj6WIDxD5_D8GWY3WEdap5E6OGxW0mJekKlycHGHiEDxKM24VKm9KHnNfM9j5wmo_rqOm0V6b0NjYHMpZ0ZalmEePxMJvoGopdI/WP_20170128_11_11_37_Rich.jpg?psid=1|here].
Same goes for the new cable ties: [https://lvdc4w-bn1305.files.1drv.com/y3pbcltp9h7He2cu2zSOX-Vvd1nu7-ZEQnId3oRfySIPYw5RGCdyzsXuCwn1wMUjCNKFdMz8TkRX3ueRj1eLRr0dxBfie7LVHhHtrbP1QUfoOaoPojJbrGKsLLYz87kIWdwO6-Wiv8ePQZoQYvKcKfJWx7hIoIngWnx_vyy1SJTdD0/WP_20170128_11_11_21_Rich.jpg?psid=1|Look here]
For me it has cost only 10,16€. And if I wanted only to replace the hydro sensor would only cost 8,93€ for me. Why have I do that because my warranty has come to an end for one year so I don't want to repair his device from the producer for a lot of money.
To open that device you need a normal cross screwdriver and for one srew you need a torx srewdriver with torx 10.
=== Update (28.01.2017) ===
To repair the p1 error you have to replace the Hydro-Stat-Modul.
I do that - look here ([https://z1xuqg-bn1305.files.1drv.com/y3pxesuoFkecFGQmNFubjE4FCwlJouF9EGNXVyIP-dm-cRh3J6pc1f_GgRJXrYUAsjusMTW8Oi2pfUR6PmC_JhI1q96I_bepgGqEwMw4jRwVnl0VlwJvAwLM5ieT86CF94Pm0X5HsSxXCVitrCkD3qa_W0hmX6oI8Dxp11E0XbmdLw/WP_20170128_11_11_10_Rich.jpg?psid=1|Picture Link]) and it works fine for me. Also you could only replace the hydro sensor on the old plate.
The new hydro-stat-modul had a short cable so I had to cut a new passway. Look [https://lvdc4w-bn1305.files.1drv.com/y3p7gs70O8Js0ObF5lBYbdpuaL9vnb4gLG7XV5pBluJK3VLSDrZ6TGdMbIljbMrRZQvmqfCdEY-uj6WIDxD5_D8GWY3WEdap5E6OGxW0mJekKlycHGHiEDxKM24VKm9KHnNfM9j5wmo_rqOm0V6b0NjYHMpZ0ZalmEePxMJvoGopdI/WP_20170128_11_11_37_Rich.jpg?psid=1|here].
Same goes for the new cable ties: [https://lvdc4w-bn1305.files.1drv.com/y3pbcltp9h7He2cu2zSOX-Vvd1nu7-ZEQnId3oRfySIPYw5RGCdyzsXuCwn1wMUjCNKFdMz8TkRX3ueRj1eLRr0dxBfie7LVHhHtrbP1QUfoOaoPojJbrGKsLLYz87kIWdwO6-Wiv8ePQZoQYvKcKfJWx7hIoIngWnx_vyy1SJTdD0/WP_20170128_11_11_21_Rich.jpg?psid=1|Look here]
For me it has cost only 10,16€. And if I wanted only to replace the hydro sensor would only cost 8,93€ for me. Why have I do that because my warranty has come to an end for one year so I don't want to repair his device from the producer for a lot of money.
To open that device you need a normal cross screwdriver and for one srew you need a torx srewdriver with torx 10.
=== Update (28.01.2017) ===
To repair the p1 error you have to replace the Hydro-Stat-Modul.
I do that - look here ([https://z1xuqg-bn1305.files.1drv.com/y3pxesuoFkecFGQmNFubjE4FCwlJouF9EGNXVyIP-dm-cRh3J6pc1f_GgRJXrYUAsjusMTW8Oi2pfUR6PmC_JhI1q96I_bepgGqEwMw4jRwVnl0VlwJvAwLM5ieT86CF94Pm0X5HsSxXCVitrCkD3qa_W0hmX6oI8Dxp11E0XbmdLw/WP_20170128_11_11_10_Rich.jpg?psid=1|Picture Link]) and it works fine for me. Also you could only replace the hydro sensor on the old plate.
The new hydro-stat-modul had a short cable so I had to cut a new passway. Look [https://lvdc4w-bn1305.files.1drv.com/y3p7gs70O8Js0ObF5lBYbdpuaL9vnb4gLG7XV5pBluJK3VLSDrZ6TGdMbIljbMrRZQvmqfCdEY-uj6WIDxD5_D8GWY3WEdap5E6OGxW0mJekKlycHGHiEDxKM24VKm9KHnNfM9j5wmo_rqOm0V6b0NjYHMpZ0ZalmEePxMJvoGopdI/WP_20170128_11_11_37_Rich.jpg?psid=1|here].
Same goes for the new cable ties: [https://lvdc4w-bn1305.files.1drv.com/y3pbcltp9h7He2cu2zSOX-Vvd1nu7-ZEQnId3oRfySIPYw5RGCdyzsXuCwn1wMUjCNKFdMz8TkRX3ueRj1eLRr0dxBfie7LVHhHtrbP1QUfoOaoPojJbrGKsLLYz87kIWdwO6-Wiv8ePQZoQYvKcKfJWx7hIoIngWnx_vyy1SJTdD0/WP_20170128_11_11_21_Rich.jpg?psid=1|Look here]
-
For me it has cost only [https://www.conrad.de/de/feuchtesensor-modul-hmz-433a1-20-90-rf-0-60-c-1170519.html|10,16€]. And if I wanted only to replace the hydro sensor would only cost [https://www.conrad.de/de/feuchtesensor-efs-10-bb-thermo-technik-feuchtesensor-efs-10-20-95-rf-0-60-c-156545.html|8,93€] for me. Why have I do that because my warranty has come to an end for one year so I don't want to repair his device from the producer for a lot of money.
+
For me it has cost only 10,16€. And if I wanted only to replace the hydro sensor would only cost 8,93€ for me. Why have I do that because my warranty has come to an end for one year so I don't want to repair his device from the producer for a lot of money.
Duracraft DD-TEC10NE: I take some pictures.
Control Plate:
http://www.fotos-hochladen.net/uploads/wp2017012518zkew6b9720.jpg
Hydro-Stat-Modul:
http://www.fotos-hochladen.net/uploads/wp2017012518rn8y0ab34m.jpg
Temperature Sensor:
http://www.fotos-hochladen.net/uploads/wp20170125180obkr5dz47.jpg
To open that device you need a normal cross screwdriver and for one srew you need a torx srewdriver with torx 10.
=== Update (28.01.2017) ===
To repair the p1 error you have to replace the Hydro-Stat-Modul.
I do that - look here ([https://z1xuqg-bn1305.files.1drv.com/y3pxesuoFkecFGQmNFubjE4FCwlJouF9EGNXVyIP-dm-cRh3J6pc1f_GgRJXrYUAsjusMTW8Oi2pfUR6PmC_JhI1q96I_bepgGqEwMw4jRwVnl0VlwJvAwLM5ieT86CF94Pm0X5HsSxXCVitrCkD3qa_W0hmX6oI8Dxp11E0XbmdLw/WP_20170128_11_11_10_Rich.jpg?psid=1|Picture Link]) and it works fine for me. Also you could only replace the hydro sensor on the old plate.
The new hydro-stat-modul had a short cable so I had to cut a new passway. Look [https://lvdc4w-bn1305.files.1drv.com/y3p7gs70O8Js0ObF5lBYbdpuaL9vnb4gLG7XV5pBluJK3VLSDrZ6TGdMbIljbMrRZQvmqfCdEY-uj6WIDxD5_D8GWY3WEdap5E6OGxW0mJekKlycHGHiEDxKM24VKm9KHnNfM9j5wmo_rqOm0V6b0NjYHMpZ0ZalmEePxMJvoGopdI/WP_20170128_11_11_37_Rich.jpg?psid=1|here].
Same goes for the new cable ties: [https://lvdc4w-bn1305.files.1drv.com/y3pbcltp9h7He2cu2zSOX-Vvd1nu7-ZEQnId3oRfySIPYw5RGCdyzsXuCwn1wMUjCNKFdMz8TkRX3ueRj1eLRr0dxBfie7LVHhHtrbP1QUfoOaoPojJbrGKsLLYz87kIWdwO6-Wiv8ePQZoQYvKcKfJWx7hIoIngWnx_vyy1SJTdD0/WP_20170128_11_11_21_Rich.jpg?psid=1|Look here]
For me it has cost only [https://www.conrad.de/de/feuchtesensor-modul-hmz-433a1-20-90-rf-0-60-c-1170519.html|10,16€]. And if I wanted only to replace the hydro sensor would only cost [https://www.conrad.de/de/feuchtesensor-efs-10-bb-thermo-technik-feuchtesensor-efs-10-20-95-rf-0-60-c-156545.html|8,93€] for me. Why have I do that because my warranty has come to an end for one year so I don't want to repair his device from the producer for a lot of money.
PS: I'm a German
To open that device you need a normal cross screwdriver and for one srew you need a torx srewdriver with torx 10.
=== Update (28.01.2017) ===
To repair the p1 error you have to replace the Hydro-Stat-Modul.
I do that - look here ([https://z1xuqg-bn1305.files.1drv.com/y3pxesuoFkecFGQmNFubjE4FCwlJouF9EGNXVyIP-dm-cRh3J6pc1f_GgRJXrYUAsjusMTW8Oi2pfUR6PmC_JhI1q96I_bepgGqEwMw4jRwVnl0VlwJvAwLM5ieT86CF94Pm0X5HsSxXCVitrCkD3qa_W0hmX6oI8Dxp11E0XbmdLw/WP_20170128_11_11_10_Rich.jpg?psid=1|Picture Link]) and it works fine for me. Also you could only replace the hydro sensor on the old plate.
The new hydro-stat-modul had a short cable so I had to cut a new passway. Look [https://lvdc4w-bn1305.files.1drv.com/y3p7gs70O8Js0ObF5lBYbdpuaL9vnb4gLG7XV5pBluJK3VLSDrZ6TGdMbIljbMrRZQvmqfCdEY-uj6WIDxD5_D8GWY3WEdap5E6OGxW0mJekKlycHGHiEDxKM24VKm9KHnNfM9j5wmo_rqOm0V6b0NjYHMpZ0ZalmEePxMJvoGopdI/WP_20170128_11_11_37_Rich.jpg?psid=1|here].
Same goes for the new cable ties: [https://lvdc4w-bn1305.files.1drv.com/y3pbcltp9h7He2cu2zSOX-Vvd1nu7-ZEQnId3oRfySIPYw5RGCdyzsXuCwn1wMUjCNKFdMz8TkRX3ueRj1eLRr0dxBfie7LVHhHtrbP1QUfoOaoPojJbrGKsLLYz87kIWdwO6-Wiv8ePQZoQYvKcKfJWx7hIoIngWnx_vyy1SJTdD0/WP_20170128_11_11_21_Rich.jpg?psid=1|Look here]
-
-
For me it has cost only [https://www.conrad.de/de/feuchtesensor-modul-hmz-433a1-20-90-rf-0-60-c-1170519.html|10,16€]. And if I wanted only to replace the hydro sensor would only cost [https://www.conrad.de/de/feuchtesensor-efs-10-bb-thermo-technik-feuchtesensor-efs-10-20-95-rf-0-60-c-156545.html|8,93€] for me. Why have I do that because my warranty has come to an end for one year so I don't want to repair his device from the producer for a lot of money.
To open that device you need a normal cross screwdriver and for one srew you need a torx srewdriver with torx 10.
=== Update (28.01.2017) ===
To repair the p1 error you have to replace the Hydro-Stat-Modul.
I do that - look here ([https://z1xuqg-bn1305.files.1drv.com/y3pxesuoFkecFGQmNFubjE4FCwlJouF9EGNXVyIP-dm-cRh3J6pc1f_GgRJXrYUAsjusMTW8Oi2pfUR6PmC_JhI1q96I_bepgGqEwMw4jRwVnl0VlwJvAwLM5ieT86CF94Pm0X5HsSxXCVitrCkD3qa_W0hmX6oI8Dxp11E0XbmdLw/WP_20170128_11_11_10_Rich.jpg?psid=1|Picture Link]) and it works fine for me. Also you could only replace the hydro sensor on the old plate.
The new hydro-stat-modul had a short cable so I had to cut a new passway. Look [https://lvdc4w-bn1305.files.1drv.com/y3p7gs70O8Js0ObF5lBYbdpuaL9vnb4gLG7XV5pBluJK3VLSDrZ6TGdMbIljbMrRZQvmqfCdEY-uj6WIDxD5_D8GWY3WEdap5E6OGxW0mJekKlycHGHiEDxKM24VKm9KHnNfM9j5wmo_rqOm0V6b0NjYHMpZ0ZalmEePxMJvoGopdI/WP_20170128_11_11_37_Rich.jpg?psid=1|here].
+
Same goes for the new cable ties: [https://lvdc4w-bn1305.files.1drv.com/y3pbcltp9h7He2cu2zSOX-Vvd1nu7-ZEQnId3oRfySIPYw5RGCdyzsXuCwn1wMUjCNKFdMz8TkRX3ueRj1eLRr0dxBfie7LVHhHtrbP1QUfoOaoPojJbrGKsLLYz87kIWdwO6-Wiv8ePQZoQYvKcKfJWx7hIoIngWnx_vyy1SJTdD0/WP_20170128_11_11_21_Rich.jpg?psid=1|Look here]
+
+
+
For me it has cost only [https://www.conrad.de/de/feuchtesensor-modul-hmz-433a1-20-90-rf-0-60-c-1170519.html|10,16€]. And if I wanted only to replace the hydro sensor would only cost [https://www.conrad.de/de/feuchtesensor-efs-10-bb-thermo-technik-feuchtesensor-efs-10-20-95-rf-0-60-c-156545.html|8,93€] for me. Why have I do that because my warranty has come to an end for one year so I don't want to repair his device from the producer for a lot of money.
To open that device you need a normal cross screwdriver and for one srew you need a torx srewdriver with torx 10.
=== Update (28.01.2017) ===
To repair the p1 error you have to replace the Hydro-Stat-Modul.
I do that - look here ([https://z1xuqg-bn1305.files.1drv.com/y3pxesuoFkecFGQmNFubjE4FCwlJouF9EGNXVyIP-dm-cRh3J6pc1f_GgRJXrYUAsjusMTW8Oi2pfUR6PmC_JhI1q96I_bepgGqEwMw4jRwVnl0VlwJvAwLM5ieT86CF94Pm0X5HsSxXCVitrCkD3qa_W0hmX6oI8Dxp11E0XbmdLw/WP_20170128_11_11_10_Rich.jpg?psid=1|Picture Link]) and it works fine for me. Also you could only replace the hydro sensor on the old plate.
+
The new hydro-stat-modul had a short cable so I had to cut a new passway. Look [https://lvdc4w-bn1305.files.1drv.com/y3p7gs70O8Js0ObF5lBYbdpuaL9vnb4gLG7XV5pBluJK3VLSDrZ6TGdMbIljbMrRZQvmqfCdEY-uj6WIDxD5_D8GWY3WEdap5E6OGxW0mJekKlycHGHiEDxKM24VKm9KHnNfM9j5wmo_rqOm0V6b0NjYHMpZ0ZalmEePxMJvoGopdI/WP_20170128_11_11_37_Rich.jpg?psid=1|here].
+
For me it has cost only [https://www.conrad.de/de/feuchtesensor-modul-hmz-433a1-20-90-rf-0-60-c-1170519.html|10,16€]. And if I wanted only to replace the hydro sensor would only cost [https://www.conrad.de/de/feuchtesensor-efs-10-bb-thermo-technik-feuchtesensor-efs-10-20-95-rf-0-60-c-156545.html|8,93€] for me. Why have I do that because my warranty has come to an end for one year so I don't want to repair his device from the producer for a lot of money.
To open that device you need a normal cross screwdriver and for one srew you need a torx srewdriver with torx 10.
=== Update (28.01.2017) ===
To repair the p1 error you have to replace the Hydro-Stat-Modul.
I do that - look here ([https://z1xuqg-bn1305.files.1drv.com/y3pxesuoFkecFGQmNFubjE4FCwlJouF9EGNXVyIP-dm-cRh3J6pc1f_GgRJXrYUAsjusMTW8Oi2pfUR6PmC_JhI1q96I_bepgGqEwMw4jRwVnl0VlwJvAwLM5ieT86CF94Pm0X5HsSxXCVitrCkD3qa_W0hmX6oI8Dxp11E0XbmdLw/WP_20170128_11_11_10_Rich.jpg?psid=1|Picture Link]) and it works fine for me. Also you could only replace the hydro sensor on the old plate.
For me it has cost only [https://www.conrad.de/de/feuchtesensor-modul-hmz-433a1-20-90-rf-0-60-c-1170519.html|10,16€]. And if I wanted only to replace the hydro sensor would only cost [https://www.conrad.de/de/feuchtesensor-efs-10-bb-thermo-technik-feuchtesensor-efs-10-20-95-rf-0-60-c-156545.html|8,93€] for me. Why have I do that because my warranty has come to an end for one year so I don't want to repair his device from the producer for a lot of money.
-
PS: I'm a German have fun and fix your devices...^^
To open that device you need a normal cross screwdriver and for one srew you need a torx srewdriver with torx 10.
=== Update (28.01.2017) ===
To repair the p1 error you have to replace the Hydro-Stat-Modul.
I do that - look here ([https://z1xuqg-bn1305.files.1drv.com/y3pxesuoFkecFGQmNFubjE4FCwlJouF9EGNXVyIP-dm-cRh3J6pc1f_GgRJXrYUAsjusMTW8Oi2pfUR6PmC_JhI1q96I_bepgGqEwMw4jRwVnl0VlwJvAwLM5ieT86CF94Pm0X5HsSxXCVitrCkD3qa_W0hmX6oI8Dxp11E0XbmdLw/WP_20170128_11_11_10_Rich.jpg?psid=1|Picture Link]) and it works fine for me. Also you could only replace the hydro sensor on the old plate.
For me it has cost only [https://www.conrad.de/de/feuchtesensor-modul-hmz-433a1-20-90-rf-0-60-c-1170519.html|10,16€]. And if I wanted only to replace the hydro sensor would only cost [https://www.conrad.de/de/feuchtesensor-efs-10-bb-thermo-technik-feuchtesensor-efs-10-20-95-rf-0-60-c-156545.html|8,93€] for me. Why have I do that because my warranty has come to an end for one year so I don't want to repair his device from the producer for a lot of money.
-
PS: I am german^^
+
PS: I'm a German have fun and fix your devices...^^
To open that device you need a normal cross screwdriver and for one srew you need a torx srewdriver with torx 10.
=== Update (28.01.2017) ===
To repair the p1 error you have to replace the Hydro-Stat-Modul.
I do that - look here ([https://z1xuqg-bn1305.files.1drv.com/y3pxesuoFkecFGQmNFubjE4FCwlJouF9EGNXVyIP-dm-cRh3J6pc1f_GgRJXrYUAsjusMTW8Oi2pfUR6PmC_JhI1q96I_bepgGqEwMw4jRwVnl0VlwJvAwLM5ieT86CF94Pm0X5HsSxXCVitrCkD3qa_W0hmX6oI8Dxp11E0XbmdLw/WP_20170128_11_11_10_Rich.jpg?psid=1|Picture Link]) and it works fine for me. Also you could only replace the hydro sensor on the old plate.
For me it has cost only [https://www.conrad.de/de/feuchtesensor-modul-hmz-433a1-20-90-rf-0-60-c-1170519.html|10,16€]. And if I wanted only to replace the hydro sensor would only cost [https://www.conrad.de/de/feuchtesensor-efs-10-bb-thermo-technik-feuchtesensor-efs-10-20-95-rf-0-60-c-156545.html|8,93€] for me. Why have I do that because my warranty has come to an end for one year so I don't want to repair his device from the producer for a lot of money.
To open that device you need a normal cross screwdriver and for one srew you need a torx srewdriver with torx 10.
=== Update (28.01.2017) ===
To repair the p1 error you have to replace the Hydro-Stat-Modul.
-
I do that - look here and it works fine for me. Also you could only replace the hydro sensor on the old plate.
+
I do that - look here ([https://z1xuqg-bn1305.files.1drv.com/y3pxesuoFkecFGQmNFubjE4FCwlJouF9EGNXVyIP-dm-cRh3J6pc1f_GgRJXrYUAsjusMTW8Oi2pfUR6PmC_JhI1q96I_bepgGqEwMw4jRwVnl0VlwJvAwLM5ieT86CF94Pm0X5HsSxXCVitrCkD3qa_W0hmX6oI8Dxp11E0XbmdLw/WP_20170128_11_11_10_Rich.jpg?psid=1|Picture Link]) and it works fine for me. Also you could only replace the hydro sensor on the old plate.
For me it has cost only [https://www.conrad.de/de/feuchtesensor-modul-hmz-433a1-20-90-rf-0-60-c-1170519.html|10,16€]. And if I wanted only to replace the hydro sensor would only cost [https://www.conrad.de/de/feuchtesensor-efs-10-bb-thermo-technik-feuchtesensor-efs-10-20-95-rf-0-60-c-156545.html|8,93€] for me. Why have I do that because my warranty has come to an end for one year so I don't want to repair his device from the producer for a lot of money.
To open that device you need a normal cross screwdriver and for one srew you need a torx srewdriver with torx 10.
=== Update (28.01.2017) ===
To repair the p1 error you have to replace the Hydro-Stat-Modul.
I do that - look here and it works fine for me. Also you could only replace the hydro sensor on the old plate.
-
For me it has cost only [https://www.conrad.de/de/feuchtesensor-modul-hmz-433a1-20-90-rf-0-60-c-1170519.html|10,16€]. And if I wanted only to replace the hydro sensor would only cost [https://www.conrad.de/de/feuchtesensor-efs-10-bb-thermo-technik-feuchtesensor-efs-10-20-95-rf-0-60-c-156545.html|8,93€] for me. Why have I do that because my warranty has come to an end for one year so I don't want to repair his device for a lot of money.
+
For me it has cost only [https://www.conrad.de/de/feuchtesensor-modul-hmz-433a1-20-90-rf-0-60-c-1170519.html|10,16€]. And if I wanted only to replace the hydro sensor would only cost [https://www.conrad.de/de/feuchtesensor-efs-10-bb-thermo-technik-feuchtesensor-efs-10-20-95-rf-0-60-c-156545.html|8,93€] for me. Why have I do that because my warranty has come to an end for one year so I don't want to repair his device from the producer for a lot of money.
To open that device you need a normal cross screwdriver and for one srew you need a torx srewdriver with torx 10.
+
+
=== Update (28.01.2017) ===
+
+
To repair the p1 error you have to replace the Hydro-Stat-Modul.
+
+
I do that - look here and it works fine for me. Also you could only replace the hydro sensor on the old plate.
+
+
For me it has cost only [https://www.conrad.de/de/feuchtesensor-modul-hmz-433a1-20-90-rf-0-60-c-1170519.html|10,16€]. And if I wanted only to replace the hydro sensor would only cost [https://www.conrad.de/de/feuchtesensor-efs-10-bb-thermo-technik-feuchtesensor-efs-10-20-95-rf-0-60-c-156545.html|8,93€] for me. Why have I do that because my warranty has come to an end for one year so I don't want to repair his device for a lot of money.
Duracraft DD-TEC10NE: I took some photos.
Control Plate:
http://www.fotos-hochladen.net/uploads/wp2017012518zkew6b9720.jpg
Hydro-Stat-Modul:
http://www.fotos-hochladen.net/uploads/wp2017012518rn8y0ab34m.jpg
Temperature Sensor:
http://www.fotos-hochladen.net/uploads/wp20170125180obkr5dz47.jpg