Zum Hauptinhalt wechseln

GermGuardian AC4825E UV-C Bulb Replacement

Was du brauchst

  1. GermGuardian AC4825E UV-C Bulb Replacement, HEPA Filter Unit: Schritt 1, Bild 1 von 1
    • Check if the purifier's power cord is plugged into an electrical outlet.

    • If it is plugged in, unplug the power cord.

  2. GermGuardian AC4825E UV-C Bulb Replacement: Schritt 2, Bild 1 von 2 GermGuardian AC4825E UV-C Bulb Replacement: Schritt 2, Bild 2 von 2
    • Grab the rear cover of the purifier with one finger on the Lock and Release button.

    • Press the button down, and pull the rear cover away from the purifier.

  3. GermGuardian AC4825E UV-C Bulb Replacement: Schritt 3, Bild 1 von 3 GermGuardian AC4825E UV-C Bulb Replacement: Schritt 3, Bild 2 von 3 GermGuardian AC4825E UV-C Bulb Replacement: Schritt 3, Bild 3 von 3
    • Use your hands to pull the HEPA filter out of the purifier.

    • After reassembly, push & hold the UV control button for 5 seconds to reset the filter change indicator.

  4. GermGuardian AC4825E UV-C Bulb Replacement, UV-C Bulb: Schritt 4, Bild 1 von 1
    • Remove the two screws from the metal UV-C shield by turning the screws counter-clockwise using a Phillips #00 screwdriver.

    • Grab and pull the UV-C shield away from the purifier to remove it.

  5. GermGuardian AC4825E UV-C Bulb Replacement: Schritt 5, Bild 1 von 3 GermGuardian AC4825E UV-C Bulb Replacement: Schritt 5, Bild 2 von 3 GermGuardian AC4825E UV-C Bulb Replacement: Schritt 5, Bild 3 von 3
    • Using a tissue or a clean cloth, reach into the exposed space and grab the UV-C bulb.

    • Pull the UV-C bulb out of the exposed space to remove the bulb from its socket.

    • After reassembly, press and hold the UV control button for 5 seconds to reset the UV bulb change indicator.

Abschluss

To reassemble your device, follow these instructions in reverse order.

Ein:e weitere:r Nutzer:in hat diese Anleitung absolviert.

Tim Lourenco

Mitglied seit: 03/28/22

305 Reputation

2 Anleitungen geschrieben

Team

UMass Dartmouth, Team 2-1, Mellen Spring 2022 Mitglied von UMass Dartmouth, Team 2-1, Mellen Spring 2022

UMASSD-MELLEN-S22S2G1

4 Mitglieder

2 Anleitungen geschrieben

Ein Kommentar

you end after you pull the bulb out. do you put another bulb in (of course) is there a right/wrong way (which side up or down) then do you plug it back in prior to holding the uv button 5 seconds? do you turn it on prior to holding the uv button 5 seconds? Please explain in detail what I should do.

william estes - Antwort

Kommentar hinzufügen

Seitenaufrufe:

Letzte 24 Stunden: 3

Letzte 7 Tage: 16

Letzte 30 Tage: 92

Insgesamt: 1,677